HOMECOMPANYPRODUCTSCONTACTPARTNERS
 
Products
Sensors for temperatur protection

                                        Sensors for temperatur protection, control and limiting 

Print E-mail
Temperature relay (miniature thermostat) RT-1



Temperature relay (miniature thermostat) RT-1The relay temperature with self-reset RT-1 are intended to operate as built-in elements inside thermal and other annunciators, including combined fire alarms, as well as for operation in electrical products for maintenance of temperature and temperature protection.

 • miniature case (the smallest thermal relay in the world)

vultralow time lag

normally closed or normally open contacts

small hysteresis

   • high reliability

 
operating principle

Material with «shape memory», manufactured using special technology, is used as the sensing element in the relay. When the environment temperature increases (up to the relay operation temperature), the sensing element (1) changes its form and affects the contact spring (2) resulting in opening (closure) of contacts. When the environment temperature decreases, relay contacts reset. 

overall and mounting dimensions in mm



Lead wire length L, mm

Lug length L1, mm

Total length L2, mm

10.0±1.0
20.0±1.0

25.0
33.5
Lug length may vary within 10.0 to 33.5 mm range as agreed.

Total length L2 is defined as the sum of lead wire length L and lug length L1, reduced by the connection length, which cannot be less than 4.0 mm.


SPECIFICATIONS

 

 

Rated voltage

 

Current rating

 

Nominal range

 

 

 

Tolerance but at least

 

Reset temperature

 

Response time

 

Electrical impedance of the contact circuit at closed contacts during operation in normal climatic conditions

 

Maximum allowable ambient temperature

 

Mass

 

Operation conditions:

environment temperature

relative humidity

 

 

atmospheric pressure

 

Average life

40 V

 

100 mA

 

plus  30; 40; 50; 60; 62; 65; 70; 80; 90; 100; 110°Ñ

 

± 2; 3; 5; 10°Ñ

 

(4.5 ± 2.5)°Ñ 

 

less than or equal to 3 sec

 

 

no more than 1.0 Ohm

 

+140°Ñ

 

no more than 0.15 g

 

-50…+125°Ñ

up to 98 % at 25°Ñ temperature without moisture condensation

 

(84,0-106,7) kPa

 

10 years

 

 
 electrical switching mode 

Current type

Load type

Voltage, V

Current,mA

Number of operating cycles

Mean time befor failure, h

Direct or alternating

Active

from 3 to 30 inclusive

from 0.1 to 30 inclusive

100

200 000

Active

from 3 to 30 inclusive

from 0.1 to 50 inclusive

50 000

10 000

Inductive

from 3 to 30 inclusive

from 0.1 to 30 inclusive

50 000

10 000



ORDER IDENTIFICATIONS



 ORDER IDENTIFICATIONS 



Types of operational labels depending on actuation temperature

Actuation temperature, °C

30

40

50

60

62

65

70

80

90

Labelcolor

blue

dark-blue

green

black

gray

yellow

red

brown

orange

Note: Relay versions are not labeled depending on case hermeticity and lead attachment methods. 

 

 

 

 

 

 

 

 

Types of labels depending on contact type

No white label - contact normally closed
White label contact normally open 

 
Temperature relay RT-1
Threshold thermistor TRP68-01