Threshold thermistor TRP68-01

  

Threshold thermistor TRP68The directly heated thermistor TRP68-01 are intended to operate as built-in elements inside thermal and other annunciators, including combined fire alarms, as well as for operation in electrical products for maintenance of temperature and temperature protection. Thermistors have relay (threshold) dependence of resistance on temperature.

 • hysteresis less than 7°Ñ

 • high reliability

• high sensitivity

• long service life

 

applications

Sensors for temperature protection, control and limiting.

Voltage, current and frequency limiters in electronics.

Examples:

→ Overtemperature protector for power semi-conductors, such as transistors, power output stages, amplifiers.

Temperature control of electronic appliances and electric equipment.

Temperature sensors for signaling systems and fire detectors.

Control of componentry in industrial and entertainment electronics.

Protection of electronic circuits, such as computers or battery chargers.

 
 operating principle

Vanadium dioxide (VO2) film is used as a temperature-sensitive element in the thermal resistor. Vanadium dioxide is a compound with metal-semiconductor phase transition (MSCPT). At a temperature below the MSCPT temperature [(68°1) C] the dependence between the thermal resistor resistance and the temperature is typical for semi-conductor materials having temperature resistance coefficient (TRC) of about 3%K-1. Thermal resistor resistance decreases stepwise near the MSCPT temperature, thus the TRC value achieves 2000%K-1. At a temperature above the MSCPT temperature the resistance remains practically the same. 

resistance-temperature relationship



 

 

 overall and mounting dimensions in mm



 THRESHOLD THERMISTOR TRP68-01

Lead wire length L, mm

Lug length L1, mm

Total length L2, mm

13.5±1.0
23.0±1.0

25.0
33.5
Lug length may vary within 10.0 to 33.5 mm range as agreed.

Total length L2 is defined as the sum of lead wire length L and lug length L1, reduced by the connection length, which cannot be less than 4.0 mm.



SPECIFICATIONS

 

 

Actuation temperature

Heat-capacity lag (deadband)

Thermal time constant

Thermistor resistance*: 
                at plus (23±3)°Ñ, R23
                at plus (50±1)°Ñ, R50

                at plus (75±1)°Ñ, R75 

Operation voltage limit

Maximum dissipation power of the thermistor over the ambient temperature ramp: 
                from -50 to +60°Ñ
                from +51 to +80°Ñ

Thermistor  power dissipation coefficient at ambient temperature plus (25±10)°Ñ

Maximum allowable ambient temperature

Mean time before failure

Terminals:        
                wire
                        
                screwed

Average storageability time

Mass

Operation conditios:
                environment temperature
                relative humidity
                atmospheric pressure
(68 ± 1)°Ñ

(5 ± 2)°Ñ

less than or equal to 4 sec 


at least 1000 kOhm
at least 250 kOhm (R50 ≥0.25 R23)

less than or equal to 0.2 kOhm (R75 ≤0.0002 R23)
38 V  


60 mW
40mW 


less than or equal to 1.5 mW/°
Ñ

+
140°
Ñ

150 000 h


d0.5 x (13.5±1); (23±1) mm
M3

8 years


no more than 0.15 g
 


-50…+125°
Ñ
(45-80)%
(84,0-106,7) kPa

 

 

 

 

 

 

 

ORDER IDENTIFICATIONS  

  

 

 

 

 

  

 

 

 

 
 
Temperature relay RT-1
Threshold thermistor TRP68-01